China Ultrapure Water System for Physical and Chemical Testing and Analysis Laboratory - China Supplier China Ultrapure Water System for Physical and Chemical Testing and Analysis Laboratory - China Supplier China Ultrapure Water System for Physical and Chemical Testing and Analysis Laboratory - China Supplier China Ultrapure Water System for Physical and Chemical Testing and Analysis Laboratory - China Supplier China Ultrapure Water System for Physical and Chemical Testing and Analysis Laboratory - China Supplier

Ultrapure Water System for Physical and Chemical Testing and Analysis Laboratory

Price:Negotiable
Industry Category: Environment Industry
Product Category:
Brand: 艾柯
Spec: Exceed-B


Contact Info
  • Add:成都市青羊區(qū)青羊工業(yè)集中發(fā)展區(qū)(西區(qū))三號園區(qū)A1棟1-2F, Zip: 610000
  • Contact: 冉經(jīng)理
  • Tel:028-87078576
  • Email:2676483902@qq.com

Other Products

Description
Additional Information

Echo Exceed Series Laboratory Ultra-Pure Water Machine

Models, Technical Parameters, Configurations

Machine Category

Exceed-Ba    Exceed-Bb

Exceed-Bc   Exceed-Bd

Machine Model

Exceed-Ba -06/12/24/32/42/50/60/80

Exceed-Bb -06/12/24/32/42/50/60/80

Exceed-BaS-06/12/24

Exceed-BbS-06/12/24

Exceed-Bc-08/16/24/32/40/60/80/100

Exceed-Bd-08/16/24/32/40/60/80/100

Exceed-Bc-S-08/16/24

Exceed-Bc-S-08/16/24

Inlet Water Source

Municipal tap water temperature 1—45℃, water pressure 1—5㎏, TDS﹤350ppm; S series is particularly suitable for high salinity areas, TDS﹤350ppm

Power Supply

220V/50HZ

Power

30W-80W

Machine Weight

25㎏-65㎏; S series 35㎏-45㎏

Main Unit Volume

Desktop: Length 450mm × Width 400mm × Height 480mm; Floor-standing: Length 450mm × Width 400mm × Height 850mm

Preparation and Water Collection Types

Dual-purpose machine, capable of simultaneously preparing and collecting two types of water quality, namely RO water and ultra-pure water

Water Quality Detection Display Configuration

Ba, Bc series equipped with three-channel, three-display, three-detection display instrument; Bb, Bd series equipped with dual-channel, dual-display, dual-detection display instrument

TOC Detection Configuration

Equipped with Exceed series dedicated Total Organic Carbon (TOC) detection display function, detection range 0~20ppb.

Water Storage Tank Configuration

Fully imported sealed vacuum pressure water storage tank: 6-32L configured with 3.2G; 40L and above configured with 11G

Ultrafiltration Membrane Configuration

Pore size 0.1μm, molecular weight cutoff 8000 dalton

Water Outlet Terminal Microfiltration

Original German imported 0.2μm capsule microfiltration (optional)

UV Configuration

None

Water Production Capacity

6L-80L per hour

8L-100L per hour

Water Collection Flow Rate

RO pure water: 1.8L/min     UP ultra-pure water: 1.5L/min

RO Pure Water Quality

Conductivity 0-10μS/cm@25℃; Impurity removal rate 99%    

Conductivity 0-15μS/cm@25℃; Impurity removal rate 98%

S series conductivity 0-4μS/cm@25℃; Impurity removal rate 99.8%

S series conductivity 0-8μS/cm@25℃; Impurity removal rate 99.5%

Water quality standard exceeds China National Laboratory Water (GB6682-2000) Grade III water standard; superior to ordinary distilled water

Ultra-Pure Water Quality

Resistivity

Resistivity 18.25ΜΩ·cm@25℃

Microparticles

(greater than 0.1μm) content: ﹤1/ml

Pyrogen

﹤0.002Eu/ml

Microorganisms

﹤1cfu/ml

Total Organic Carbon

TOC: ﹤3 ppb

TOC: ﹤5 ppb

Silicate

﹤2ppb

﹤4ppb

﹤2ppb

Metal Cation Content (ppb)

Fe (Iron) ﹤0.005     Cu (Copper) ﹤0.005   Al (Aluminum) ﹤0.005   Ni (Nickel) ﹤0.005

Zn (Zinc) ﹤0.02      Cr (Chromium) ﹤0.005   Na (Sodium) ﹤0.01    K (Potassium) ﹤0.02

Anion Content (ppb)

Clˉ (Chloride) ﹤0.01  NO2ˉ (Nitrite) ﹤0.02  NO3ˉ (Nitrate) ﹤0.02   SO42ˉ (Sulfate) ﹤0.01

Compliance Standards

China Pharmacopoeia 2010 Edition Purified Water Standard

US CAP, ASTM, NCCLS Water Quality Standards

ISO-3696 Laboratory Analytical Reagent Water Standard

China Analytical Laboratory Water Specification (GB6682-2000) Grade I Water Standard

China National Electronic Grade Ultra-Pure Water Specification (GB/T11446.1-1997) EW-I Standard

Standard Configuration

PP→AC→AC→RO→DI→UP→UF→MF

PP→AC→AC→RO→UP→UF→MF

S Series Standard Configuration

PP→AC→AC→RO→RO→DI→UP→UV→UF→MF

PP→AC→AC→RO→RO→UP→UV→UF→MF

Application Scope

Water for physical and chemical detection analysis, biochemical analysis, blood analysis, trace analysis, environmental analysis, drug composition analysis, ICP-MS, GC-MS, LC-MS, ICP, HPLC, GC, AAS, PCR, TOC, and other high-standard laboratory research, analysis, and testing in various industries


Industry Category Environment Industry
Product Category
Brand: 艾柯
Spec: Exceed-B
Stock:
Origin: China / Sichuan / Chengdushi
About Toocle.com - Partner Programme - Old Version
Copyright ? Toocle.com. All Rights Reserved.
(浙)-經(jīng)營性-2023-0192
ChatGlobal Chat Me 河曲县| 朝阳区| 和田县| 南岸区| 海原县| 凤庆县| 武陟县| 扶绥县| 高尔夫| 那坡县| 盈江县| 高唐县| 微山县| 万年县| 临夏县| 彩票| 太仓市| 辽中县| 手机| 克拉玛依市| 双桥区| 横峰县| 神池县| 钟山县| 河东区| 乌海市| 屯门区| 寿光市| 堆龙德庆县| 台南县| 阿拉善左旗| 福泉市| 白银市| 嘉禾县| 巢湖市| 苏尼特右旗| 永善县| 东丰县| 浪卡子县| 陆丰市| 清徐县|