Additional Information


Instrument Principle:

When monochromatic light passes through the measured solution, its energy is absorbed. The intensity of light absorption is proportional to the concentration of the substance being measured, in accordance with Lambert-Beer's Law: A = log(1/T) = log(I?/I) = a × b × c.

Standard "HJ 637-2018 Water Quality - Determination of Petroleum and Animal Oils - Infrared Spectrophotometry" uses tetrachloromethane to extract petroleum substances from water to determine petroleum content.

Compliant Standards:

Complies with standard HJ 637-2018 "Water Quality - Determination of Petroleum and Animal and Vegetable Oils - Infrared Spectrophotometry"

Complies with standard HJ 1077-2019 "Stationary Source Emission - Determination of Oil Fume and Oil Mist - Infrared Spectrophotometry"

Complies with standard: HJ 1051-2019 "Soil - Determination of Petroleum - Infrared Spectrophotometry"

Complies with standard GB 18483-2001 "Emission Standard for Cooking Fume"

Complies with standard GB 3838-2002 "Environmental Quality Standards for Surface Water"

Complies with standard GB 18918-2002 "Discharge Standard of Pollutants for Municipal Wastewater Treatment Plant"

Complies with petroleum standard SY/T 0530-2011 "Determination of Oil Content in Oilfield Produced Water by Spectrophotometry"

Complies with oilfield standard DB65/T 3998-2017 "Pollution Control Requirements for Comprehensive Utilization of Oily Sludge in Oil and Gas Fields"

Technical Parameters

l Uses pulsed light source for information reception and output

l Technical principle: Motor subdivision-driven grating spectrophotometry technology

l Cooling technology: Semiconductor-cooled light source to eliminate temperature errors

l Baseline drift correction system, output signal without drift

l Blank solvent zeroing: Automatic saving; measurement data: Automatic calculation of results

l Instrument scanning range: 3400 cm?1 to 2400 cm?1 (2930 cm?1, 2960 cm?1, 3030 cm?1)

l Absorbance range: 0.00000–2.00000 AU

l Measurement range: 0–80,000.00 mg/L

l Resolution: 0.001 mg/L

l Maximum measurement concentration: 100

l Wavenumber accuracy and repeatability: ±0.5 cm?1

l Linear correlation coefficient R > 0.999

l Methyl resolution > 2%

l Sample analysis time: 0–60 seconds

l Ambient temperature: 2°C–40°C, relative humidity: 10%–90%

Instrument Functions

l Measurement targets: Oil content in water, soil, catering oil fumes, gases, and other substances

l Continuous spectral scanning function, high-contrast sample spectra, accurate determination of oil content results, automatic calculation, automatic storage of 100,000 data entries including results, test spectra, and set conditions; query and print detection reports; features mathematical statistics, spectral display, storage, and other functions.

l Visual operation interface, guided operation procedure.

l Unaffected by room temperature changes; continuous analysis and testing with automatic temperature compensation.

l Analysis system compatible with Windows 7, Windows 10, Windows 11.

l Fast calibration mode, meeting both standard and metrological specifications, as well as international standards.

l Uses imported optical platform system, short optical path, high energy, meeting infrared spectroscopy requirements, with good stability and signal-to-noise ratio.

l Detachable integrated optical system, compact instrument size, short optical path, high energy; spectrally separated before absorption, meeting infrared spectroscopy requirements, with excellent stability and high signal-to-noise ratio.

l 24-bit, 500 kHz A/D conversion, high-speed USB 2.0 interface, compatible with USB 3.0 high-performance electronic system, enabling real-time spectral data acquisition with data authenticity and reliability.

l Uses advanced switching power supply light source, reducing heat generation for better system cooling, while simplifying instrument structure and improving reliability by reducing mechanical light-chopping components.

l Unaffected by room temperature changes: Continuous analysis and testing with automatic temperature compensation.

l Compatible with various environmentally friendly reagents.

l Features instrument calibration coefficient function: Single-point fast calibration, standard curve calibration, and three national standard substance calibrations.

l Storage function: Main unit can store sample ID, detection time, detection results, type of extraction solvent, and other information.

Industry Category
Product Category
Brand: 繽磁
Spec: LS3060
Stock:
Origin: China / Shanghai / Fengxianqu
About Toocle.com - Partner Programme - Old Version
Copyright ? Toocle.com. All Rights Reserved.
(浙)-經(jīng)營(yíng)性-2023-0192
ChatGlobal Chat Now 得荣县| 日照市| 辽宁省| 垫江县| 邳州市| 泗阳县| 青浦区| 饶河县| 财经| 明水县| 涟源市| 蚌埠市| 吉安市| 弥勒县| 文昌市| 资兴市| 信阳市| 南安市| 密山市| 洪泽县| 沙雅县| 邓州市| 罗山县| 于田县| 沂南县| 巧家县| 保定市| 濮阳县| 张家界市| 五家渠市| 桓台县| 湘阴县| 北碚区| 福海县| 克拉玛依市| 民权县| 金坛市| 本溪| 杭锦后旗| 洛川县| 新田县|