Portable Infrared Gas Analyzer

Price:¥1
Industry Category:
Product Category:
Brand: 天禹智控
Spec: TY-6300P


Contact Info
  • Add:東湖新技術(shù)開發(fā)區(qū)武大科技園興業(yè)樓北樓1單元100, Zip: 430074
  • Contact: 王靜
  • Tel:13469970286
  • Email:

Other Products

Description
Additional Information

Product Details

1. Product Real Shot

2. Dimensions

3. Weight: 2.5kg

4. Product Introduction

The portable infrared gas analyzer TY-6300P adopts the world's most advanced NDIR non-dispersive infrared technology, primarily used to measure the volume concentration and calorific value of gases such as CO, CO?, CH?, C?H?, SO?, and NO in gas mixtures. It features high measurement accuracy, simple structure, convenient maintenance, powerful software functionality, strong expandability, and excellent field practicality. It is currently popular both domestically and internationally.

It is suitable for applications in steel, chemical, coal gasification, bio-gasification, energy-saving monitoring, energy efficiency evaluation, and other fields. It measures the volume concentration of different components in combustible gases such as coke oven gas, blast furnace gas, converter gas, mixed gas, generator gas, and biogas.

5. Advantages and Features

(1) Black anodized finish, fashionable appearance, strong technological feel. The instrument is lightweight and compact, with dimensions of only 136mm*136mm*270mm.

(2) The sensor uses fully imported NDIR non-dispersive infrared sensors.

(3) The instrument measures the volume concentration of CO, CO?, CH?, C?H?, NO, and SO? in gases. It includes an over-range limit enable function, ensuring measurement accuracy within the range while allowing over-range measurements for reference.

(4) Automatic correction of internal gas interference ensures interference-free measurement results.

(5) The instrument features an intelligent user calibration gas concentration determination function to prevent misuse that could render the instrument inoperable.

(6) Fast detection time, completing the entire detection process within one minute.

(7) The instrument automatically performs the entire process of gas sampling, analysis, and detection. Compared to Orsat and chromatographic gas analyzers, it has no complex operational steps, requires no long waiting times for measurements, and uses no consumables.

(8) Simple operation and portability; personnel can operate it after on-site training.

(9) Diverse application scenarios. Suitable for direct sampling tests on industrial site pipelines as well as laboratory gas bag sampling analysis.

(10) Built-in lithium battery, soft-start power switch, intelligent battery management, low battery alarm to prevent operation under low battery conditions.

(11) Chinese and English software operating systems can be freely switched.

(12) Powerful software functionality, including automatic data storage, query, deletion, USB export, etc. Historical data storage site names can be customized (supports Chinese input), and measurement data storage intervals can be user-defined.

(13) Equipped with an RS-485 digital output interface.

(14) Built-in imported sampling pump with display and settable sampling flow rate. The sampling pump status can be dynamically tuned to meet various pressure conditions for field testing.

(15) Can connect to external pretreatment devices to enhance field measurement accuracy and protect the instrument.

(16) Modular design, remote software version upgrade capability.   

6. Technical Parameters

(1) Measurement indicators: CO, CO?, CH?, C?H?, NO, SO?

(2) Measurement method: NDIR non-dispersive infrared

(3) Range: CO, CO?, CH?, C?H?: 0~100%... ... (Range configurable based on user requirements)

(4) Resolution: CO, CO?, CH?, C?H?, SO?, NO: 0.01% (For low ranges, resolution can reach 1ppm)

(5) Accuracy: CO, CO?, CH?, C?H?, SO?, NO: ≤±1%FS

(6) Repeatability error: CO, CO?, CH?, C?H?, SO?, NO: ≤1%

(7) Optimal flow rate: 0.7~1.2 L/min

(8) Inlet pressure: 2KPa~50KPa

(9) Sample gas requirements: Dust-free, water-free, oil-free

(10) Response time: (TD+T90)<10s (NDIR)

(11) Signal output: RS-232 digital output, 4-20mA analog output

(12) Operating power supply: AC220V 50HZ

7. Field Cases

Application Fields

Suitable for steel, chemical, coal gasification, bio-gasification, energy-saving monitoring, energy efficiency evaluation, and other fields. Measures the volume concentration and calorific value of different components in combustible gases such as coke oven gas, blast furnace gas, converter gas, mixed gas, generator gas, and biogas.