1. Product Real Shot

2. Dimensions 136mm*136mm*270mm

3. Weight 2.5kg

4. Product Overview

The portable infrared biogas analyzer TY-6020P, developed by Wuhan Tianyu Zhikong, adopts the world's most advanced NDIR non-dispersive infrared technology and ECD electrochemical technology. It is mainly used to measure the volume concentration of six gases—CO, CO2, CH4, H2, O2, and H2S—in various biogas and bio-gas. The portable infrared biogas analyzer is compact, lightweight, easy to carry, highly accurate, structurally simple, easy to maintain, equipped with powerful software, highly expandable, and practical for on-site use. It is currently popular both domestically and internationally, suitable for rural energy offices, livestock farmers, agricultural growers, kitchen waste treatment plants, sewage treatment plants, paper mills, wineries, pharmaceutical factories, citric acid plants, landfills, engineering companies, universities, and research institutes to detect gas volume concentration and calorific value in anaerobic fermentation processes and experiments.

5. Advantages and Features

(1) Black anodized finish, fashionable appearance, strong technological feel, lightweight instrument, compact size, dimensions only 136mm*136mm*270mm.

 

(2) Uses imported NDIR non-dispersive infrared sensors and ECD electrochemical gas sensors.

(3) The instrument measures the volume concentration of six gases in the sample gas: CO, CO2, CH4, H2, O2, and H2S. Added over-range limit enable function ensures measurement accuracy within the range, and over-range measurement is possible, providing reference values.

(4) Automatic correction of internal gas interference ensures interference-free measurement results.

(5) The instrument features intelligent judgment of user calibration gas concentration to prevent misuse that could render the instrument inoperable.

(6) Fast detection time, completing the entire detection process within one minute.

(7) The instrument automatically samples, analyzes, and detects. Compared to gas analysis methods like Orsat and chromatography, it is easy to operate, fast in measurement, and requires no consumables.

(8) Simple operation, portable, users can operate it after on-site training.

(9) Suitable for both direct sampling testing from industrial pipelines and laboratory gas bag sampling analysis.

(10) Built-in lithium battery, soft-start power switch, intelligent battery management, low battery alarm to prevent operation under low power conditions.

(11) Chinese and English software operating systems can be freely switched.

(12) Powerful software functions include automatic data storage, query, deletion, USB export, etc. Historical data storage site names can be customized (supports Chinese input), and measurement data storage intervals can be set.

(13) Equipped with RS-485 digital output interface.

(14) Built-in imported sampling pump with display and adjustable sampling flow, dynamically tunable pump status to meet various pressure conditions for on-site testing.

(15) Can connect to external pretreatment devices to enhance on-site measurement accuracy and protect the instrument.

(16) Modular design, software version can be upgraded remotely.   

6. Technical Parameters

(1) Measurement indicators: CO, CO2, CH4, H2, O2, H2S (can optionally display concentration and calorific value of 1-6 components)

(2) Measurement methods: CO, CO2, CH4: NDIR non-dispersive infrared; H2: TCD thermal conductivity; O2, H2S: ECD electrochemical

  • Range: CO: 0-2000ppm, CO2: 0-50% , CH4: 0-100%, H2: 0-1000ppm, O2: 0-25%, H2S: 0-9999ppm (range can be configured according to user needs)

(4) Resolution: CO2, CH4, O2: 0.01%; CO, H2, H2S: 1ppm

(5) Accuracy: CO2, CH4: ≤±1%FS; CO, O2, H2, H2S: ≤±2%FS

(6) Repeatability error: CO, CO2, CH4, H2, O2, H2S: ≤1%  

(7) Optimal flow rate: 0.7-1.2L/min

(8) Inlet pressure: 2kPa-50kPa

(9) Sample gas requirements: Dust-free, water-free, oil-free

(10) Response time: T90<10s (NDIR)

(11) Signal output: RS-485 digital output

(12) Power supply: Built-in rechargeable lithium battery     External 12.6V charger

7. On-site Cases

Application Fields

Suitable for rural energy offices, livestock farmers, agricultural growers, kitchen waste treatment plants, sewage treatment plants, paper mills, wineries, pharmaceutical factories, citric acid plants, landfills, engineering companies, universities, and research institutes to measure volume concentration and calorific value of different components in biogas.

Industry Category