色播婷婷电影综合社区,AV女优不卡亚洲在线,99999AV,日韩人妻中文字幕视频,国产拍自偷,91人人妻,超碰在线81,免费福利视频一区,九草青草原在线看

China WZJ Type Microorganism Tester Calibration Device (Turbidimetric Method) - China Supplier
China WZJ Type Microorganism Tester Calibration Device (Turbidimetric Method) - China Supplier

WZJ Type Microorganism Tester Calibration Device (Turbidimetric Method)

Price:Negotiable
Industry Category:
Product Category:
Brand: 通量科技
Spec: WZJ型


Contact Info
  • Add:深圳市龍崗區(qū)銷售熱線:15914142916, Zip: 518116
  • Contact: 馮先生
  • Tel:15914142916
  • Email:186jl@163.com

Other Products

Description
Additional Information

MWYJ Type Standard Device for Inhibition Zone Analyzer   Microbial Analyzer Calibration Device (Cylinder Plate Method)

WZJ Type Microbial Analyzer Calibration Device (Turbidimetric Method)

Standard Template for Calibration of Microbial Detection Systems

Calibration Device for Microbial Turbidimetric Analyzer

Calibration Standard Plate for Inhibition Zone Analyzer (Two-Dose and Three-Dose, 2 plates)

1. Flux Technology (Nantong) Co., Ltd. The MWYJ Type Standard Device for Inhibition Zone Analyzer consists of standard templates with a diameter of 90mm. The standard templates reproduce the value range of inhibition zones, covering the size requirements (12.5–25) mm specified in the national pharmacopoeia for the cylinder plate method of antibiotic microbiological assay. The expanded uncertainty is better than 0.02 mm.

2. The two-dose calibration standard plate contains four circular holes: S1, S2, T1, and T2.

Hole diameter: S1 < S2, T1 < T2. The nominal diameters of the holes are: S2 = T2 = 21 mm, S1 = T1 = 17 mm.

3. The three-dose calibration standard plate contains six circular holes: S1, S2, S3, T1, T2, and T3.

Hole diameter: S1 < S2 < S3, T1 < T2 < T3. The nominal diameters of the holes are: S1 = T1 = 13.5 mm, S2 = T2 = 16.5 mm, S3 = T3 = 19.5 mm.

Fully compliant with the requirements of JJF1614-2017 "National Metrological Calibration Specification for Antibiotic Potency Analyzers," it can serve as a metrological standard for calibration of microbial analyzers (inhibition zone analyzers) using the cylinder plate method by metrological technical institutions.

Calibration Standard Plate for Inhibition Zone Analyzer (Linearity and Edge Effect, 2 plates)

1. Flux Technology (Nantong) Co., Ltd. The GDJ Type Standard Device for Inhibition Zone Analyzer consists of standard templates with a diameter of 90 mm. The standard templates reproduce the value range of inhibition zones, covering the size requirements (12.5–25) mm specified in the national pharmacopoeia for the cylinder plate method of antibiotic microbiological assay. The expanded uncertainty is better than 0.02 mm.

2. The linearity calibration standard plate contains six circular holes: T1, T2, T3, T4, T5, and T6.

Nominal hole diameters: T1 = 12.5 mm, T2 = 15.0 mm, T3 = 17.5 mm, T4 = 20.0 mm, T5 = 22.5 mm, T6 = 25.0 mm. The six sample holes are evenly distributed on the standard plate.

3. The edge effect calibration standard plate contains four circular holes: T1, T2, T3, and T4.

Nominal hole diameters: T1 = T2 = T3 = T4 = 17.0 mm. The four holes are distributed in four directions on the standard plate, with the geometric centers of the holes located at distances of 18.5 mm, 23.5 mm, 28.5 mm, and 32.5 mm from the geometric center of the entire calibration plate.

It can be used by metrological technical institutions for calibration of microbial analyzers (inhibition zone analyzers) using the cylinder plate method.

Standard Device for Microbial Analyzer (Turbidimetric Method)

1. Flux Technology (Nantong) Co., Ltd. The WZJ Type Calibration Device for Microbial Turbidimetric Analyzer consists of three specialized test fixtures and four absorbance standard blocks. The light transmission hole size of the absorbance standard blocks is 29 mm × 8 mm, fully meeting the calibration requirements of microbial turbidimetric analyzers currently available on the market.

2. The nominal absorbance values of the absorbance standard blocks are 0.3, 0.5, 0.7, and 1.0, calibrated at wavelengths of 530 nm and 580 nm. The relative expanded uncertainty of the absorbance standard values is better than 2% (k=2).

Compliant with the requirements of JJF1614-2017 "National Metrological Calibration Specification for Antibiotic Potency Analyzers," it can serve as a metrological standard for calibration of microbial turbidimetric analyzers by metrological technical institutions.


Industry Category
Product Category
Brand: 通量科技
Spec: WZJ型
Stock:
Origin: China / Jiangsu / Nantongshi
About Toocle.com - Partner Programme - Old Version
Copyright ? Toocle.com. All Rights Reserved.
(浙)-經(jīng)營(yíng)性-2023-0192
ChatGlobal Chat Now 永登县| 永州市| 麦盖提县| 贞丰县| 宝清县| 内江市| 克什克腾旗| 东丽区| 彩票| 左云县| 高碑店市| 津南区| 大足县| 雷州市| 杭州市| 洛浦县| 上高县| 辉南县| 叶城县| 澎湖县| 安阳市| 万安县| 军事| 南丹县| 科技| 松溪县| 巧家县| 富锦市| 郯城县| 丰县| 东乡县| 丰城市| 莲花县| 万盛区| 玉溪市| 荥阳市| 崇礼县| 涞源县| 隆安县| 文安县| 钟祥市|