色播婷婷电影综合社区,AV女优不卡亚洲在线,99999AV,日韩人妻中文字幕视频,国产拍自偷,91人人妻,超碰在线81,免费福利视频一区,九草青草原在线看

China 1P Wall-mounted Explosion-proof Air Conditioner BFKT-2.6 Chemical Plant Explosion-proof Air Conditioner - China Supplier
China 1P Wall-mounted Explosion-proof Air Conditioner BFKT-2.6 Chemical Plant Explosion-proof Air Conditioner - China Supplier China 1P Wall-mounted Explosion-proof Air Conditioner BFKT-2.6 Chemical Plant Explosion-proof Air Conditioner - China Supplier China 1P Wall-mounted Explosion-proof Air Conditioner BFKT-2.6 Chemical Plant Explosion-proof Air Conditioner - China Supplier

1P Wall-mounted Explosion-proof Air Conditioner BFKT-2.6 Chemical Plant Explosion-proof Air Conditioner

Price:¥4350 /臺
Industry Category: Lighting
Product Category:
Brand: 百科特奧
Spec: BFKT-2.6


Contact Info
  • Add:浙江省杭州市余杭區(qū)閑林街道嘉企路15號1幢南三層, Zip: 311100
  • Contact: 鄭學(xué)樂
  • Tel:13357144970
  • Email:1013522671@qq.com

Other Products

Description
Additional Information

1P Wall-mounted Explosion-proof Air Conditioner BFKT-2.6 Chemical Plant Explosion-proof Air Conditioner


The Baiketeao explosion-proof air conditioner series, processed with special explosion-proof technology, can be widely used in Zone 1 and Zone 2 explosion-proof levels, covering various industries such as national defense, scientific research, petroleum, chemical, pharmaceutical, processing and manufacturing, and biopharmaceuticals. It is designed for hazardous locations where flammable gases, vapors, and air mixtures of Class IIA, IIB, IIC, and T1 to T4 groups are present, and where temperature control is required. The Baiketeao explosion-proof air conditioner series products have all passed the inspection of the National Center for Quality Supervision and Testing of Explosion-proof Electrical Products and obtained the national explosion-proof certification for explosion-proof electrical equipment. The Baiketeao brand explosion-proof air conditioner series features an aesthetically pleasing appearance, reasonable design, and convenient installation and maintenance. Internally, it uses brand compressors, microcomputer control, and digital display, with advantages such as low noise, stable performance, and easy operation, making it highly favored by customers in special industries.

The execution standards are as follows:

GB/T3836.1-2021 Explosive Atmospheres Part 1: Equipment: General Requirements

GB/T3836.2-2021 Explosive Atmospheres Part 2: Equipment Protected by Flameproof Enclosure "d"

GB/T3836.4-2021 Explosive Atmospheres Part 4: Equipment Protected by Intrinsic Safety "i"

GB/T3836.9-2021 Explosive Atmospheres Part 9: Equipment Protected by Encapsulation "m"

GB/T3836.15-2017 Explosive Atmospheres Part 15: Design, Selection, and Installation of Electrical Installations

JB/T10538-2005 Explosion-proof Dehumidifiers and Air Conditioners


I. Composition of Explosion-proof Air Conditioners:

Explosion-proof air conditioners are not ordinary air conditioning products but are explosion-proof electrical appliances used in specific industries. Explosion-proof air conditioners have cooling, heating, and automatic defrosting functions, but components such as compressors and fans have undergone special explosion-proof treatment. The composition of explosion-proof air conditioners includes air inlets, air outlets, drainage pipes, connecting pipes, and outdoor units. The outdoor unit consists of a compressor, exhaust fan, heat exchanger, and capillary tube.




II. Environmental Requirements for Explosion-proof Air Conditioners:

1. The cabinets designed for explosion-proof air conditioners are becoming smaller. As a result, electronic components inside the cabinets are arranged more densely, and the heat dissipation per unit volume of the cabinet is increasing. If heat is not discharged in time, the temperature of electronic components and the surrounding environment will gradually rise, shortening the service life of the explosion-proof air conditioner. When the ambient temperature of components exceeds 65°C, equipment failure is likely to occur. Therefore, it is advisable to avoid using explosion-proof air conditioners in excessively high temperatures.

2. Explosion-proof air conditioners have requirements not only for temperature but also for humidity. If the relative humidity is too low, strong static electricity may generate inside the equipment room, leading to operational failures of the explosion-proof air conditioner. Therefore, the humidity inside the explosion-proof air conditioner should be controlled between 45% and 65%.


III. Installation Requirements for Explosion-proof Air Conditioners:

The installation requirements for explosion-proof air conditioners are stricter compared to ordinary air conditioners. If installation requirements are not met or maintenance is not timely, accidents are likely to occur. For example, if the metal外殼 of electrical equipment such as indoor and outdoor air conditioners is not grounded, or if the grounding device has excessive resistance or poor welding, hazardous situations may arise. Explosion-proof air conditioners generally use original Gree air conditioners, which offer high quality and high safety.



Industry Category Lighting
Product Category
Brand: 百科特奧
Spec: BFKT-2.6
Stock: 68
Manufacturer:
Origin: China / Zhejiang / Hangzhoushi
About Toocle.com - Partner Programme - Old Version
Copyright ? Toocle.com. All Rights Reserved.
(浙)-經(jīng)營性-2023-0192
镇雄县| 岑溪市| 德昌县| 保定市| 新河县| 同仁县| 石棉县| 宜都市| 东乌珠穆沁旗| 徐州市| 青海省| 江油市| 肥乡县| 高唐县| 新郑市| 新闻| 德江县| 天津市| 临安市| 五莲县| 黄平县| 临洮县| 景东| 辽阳市| 阜新市| 收藏| 廊坊市| 莱西市| 文成县| 淳安县| 二连浩特市| 福州市| 沧州市| 凤庆县| 全南县| 莎车县| 海门市| 鄄城县| 安宁市| 额济纳旗| 海南省|