色播婷婷电影综合社区,AV女优不卡亚洲在线,99999AV,日韩人妻中文字幕视频,国产拍自偷,91人人妻,超碰在线81,免费福利视频一区,九草青草原在线看

China Single Wire and Cable Vertical Flame Test Apparatus - China Supplier
China Single Wire and Cable Vertical Flame Test Apparatus - China Supplier China Single Wire and Cable Vertical Flame Test Apparatus - China Supplier China Single Wire and Cable Vertical Flame Test Apparatus - China Supplier China Single Wire and Cable Vertical Flame Test Apparatus - China Supplier China Single Wire and Cable Vertical Flame Test Apparatus - China Supplier

Single Wire and Cable Vertical Flame Test Apparatus

Price:¥20000 /臺(tái)
Industry Category:
Product Category:
Brand: 今森
Spec: KS-54D


Contact Info
  • Add:上海市奉賢區(qū)南橋鎮(zhèn)萬賓路235號(hào)1號(hào)樓, Zip:
  • Contact: 魯麗
  • Tel:13916948217
  • Email:ks_shanghai@163.com

Other Products

Description
Additional Information

Scope of Application: The Single Wire and Cable Vertical Flame Test Apparatus, also known as the Single Wire and Cable Vertical Flame Chamber or Single Wire and Cable Vertical Flame Tester, is suitable for testing the flame resistance of various insulating sheath materials for wires and cables, such as PE, PVC, and SRPVC. During testing, it is manufactured in accordance with the GB/T18380.11-2022 test standard. The specimen is fixed at both ends and placed vertically in a metal enclosure with three metal panels. The burner is ignited, and the tip of the blue inner cone is made to contact the surface of the specimen while keeping the burner at a 45° angle to the vertical axis of the specimen.

Compliance Standards: Complies with GB/T18380.11-2022, GB/T18380.12-2022, GB/T18380.21-2008, GB/T18380.22-2008, IEC60332-1, and GB/T5169.14-2017 test standards.

Vertical Flame Test Method

This standard specifies the test method and requirements for the vertical flame test of a single insulated wire or cable under flame conditions.

The test method specified in this standard is not applicable to small wires with a diameter of less than 0.8mm or small stranded wires with a cross-sectional area of less than 0.5mm2, as their conductors may melt before the test is completed.

Before testing, all specimens should reach thermal equilibrium under conditions of temperature (23±5)°C and relative humidity (50±20)% (conditioned for at least 16 hours).

If the surface of the insulated wire or cable has a coating or varnish layer, the specimen should be placed at a temperature of (60±2)°C for 4 hours before undergoing the above conditioning.

Purpose and Composition of the Single Wire and Cable Vertical Flame Tester

This equipment is used to determine the non-propagating flame characteristics of wires under direct flame exposure from a specified ignition source.

The equipment mainly consists of three parts: the control box, the vertical flame test chamber, and the burner.

Main Technical Parameters

No.

Item

Parameter

1

Burner (compliant with GB/T18380.11)

Inner diameter Φ12mm ± 0.5mm

2

Burner (compliant with GB/T18380.11)

Inner diameter Φ9.5mm ± 0.5mm (one Bunsen burner)

3

Test tilt angle

45°

4

Flame height

Adjustable from 20mm ± 2mm to 190mm ± 1mm

5

Flame application time

Adjustable 0-999.9s ± 0.1s

6

After-flame time

0-999.9s ± 0.1s, automatically recorded, manually pausable

7

Combustion gas

95% propane gas (generally, liquefied petroleum gas can be used as a substitute)

8

Flow pressure

Equipped with dual flow meters and pressure gauges (for gas and air)

9

Temperature test range

0~1000°C

10

Flame temperature requirement

Time from 100°C ± 5°C to 700°C ± 3°C within 46 seconds ± 6 seconds

11

Flame should continuously burn the specimen

Flame burning time T setting range 0.1-999.9 (seconds), continuously adjustable

12

Temperature measurement thermocouple

Φ0.5mm imported armored thermocouple (Type K)

13

Test process

Automatically controlled test procedure, no independent exhaust

14

Gas

High-purity propane gas or liquefied petroleum gas

15

Length of tested wire or cable

600 ± 25mm

16

Outer diameter of tested wire or cable

Conductor diameter greater than 0.8mm or cross-sectional area greater than 0.5mm2

17

The device should be placed in a non-ventilated environment with a temperature of

(23 ± 10)°C for testing

18

Selector switch can be chosen according to actual needs

Manual or automatic

19

Gas flow range

0.1-1L/min

20

Air flow range

0.1-1m3/h

21

Standard power of the burner

1KW

22

Power supply voltage

220V/50Hz

23

Chassis material

Electrostatically sprayed steel plate / or stainless steel chassis, no visible weld marks

24

Working chamber dimensions

300x450x1200mm (0.16 cubic meters)

Included Items List

No.

Name

Unit

Quantity


1

Instruction manual

copy

1


2

Single Wire and Cable Vertical Flame Test Apparatus

unit

1


3

Stainless steel ruler

piece

1


4

Exhaust pipe

piece

1


5

Power cord

piece

1


6

Hose clamp

piece

2


7





8





9





10





11











Optional accessories (additional charge, must be requested at time of purchase)


Industry Category
Product Category
Brand: 今森
Spec: KS-54D
Stock: 10000
Manufacturer:
Origin: China / Shanghai / Fengxianqu
About Toocle.com - Partner Programme - Old Version
Copyright ? Toocle.com. All Rights Reserved.
(浙)-經(jīng)營性-2023-0192
ChatGlobal Chat Now 老河口市| 中西区| 铜川市| 威远县| 天水市| 德清县| 林周县| 龙井市| 延川县| 扬中市| 德江县| 穆棱市| 始兴县| 灵台县| 葵青区| 当雄县| 崇阳县| 息烽县| 凭祥市| 页游| 海南省| 宁城县| 南京市| 通江县| 黄平县| 开鲁县| 新蔡县| 横峰县| 杭锦旗| 永丰县| 嘉兴市| 陕西省| 达日县| 桦甸市| 吴堡县| 边坝县| 郑州市| 修水县| 怀集县| 丰顺县| 乐亭县|