色播婷婷电影综合社区,AV女优不卡亚洲在线,99999AV,日韩人妻中文字幕视频,国产拍自偷,91人人妻,超碰在线81,免费福利视频一区,九草青草原在线看

China TUV.SV.19-SFA15T2245 Refrigeration Safety Valve - China Supplier
China TUV.SV.19-SFA15T2245 Refrigeration Safety Valve - China Supplier China TUV.SV.19-SFA15T2245 Refrigeration Safety Valve - China Supplier China TUV.SV.19-SFA15T2245 Refrigeration Safety Valve - China Supplier China TUV.SV.19-SFA15T2245 Refrigeration Safety Valve - China Supplier China TUV.SV.19-SFA15T2245 Refrigeration Safety Valve - China Supplier

TUV.SV.19-SFA15T2245 Refrigeration Safety Valve

Price:¥2100 /個
Industry Category:
Product Category:
Brand: Danfoss
Spec: SFA15T224,SFA15T225


Contact Info
  • Add:白云區(qū)機場路585號鵬景大廈1106-07, Zip:
  • Contact: 柯先生
  • Tel:020-36218410
  • Email:178000208@qq.com

Other Products

Description
Additional Information

Product Introduction of TUV.SV.19-SFA15T2245 Refrigeration Safety Valve

The SFA15 angle-type safety valve is a typical back-pressure relief valve, specifically designed to protect containers or other components from overpressure.The valve design meets the stringent quality and safety requirements of refrigeration installations,as well as other international certification standards.In refrigeration systems, it is recommended for use as an internal or external safety valve.The spring housing is tightly sealed to prevent refrigerant leakage.

The inlet diameter of the valve is:- 13 mm (? in.) SFA 15Valves with set pressures ranging from 10 to 40 bar g (145 to580 psi g) are available.Each valve can be supplied as a safety valve with a standard pressure setting certified by TüV.

Refrigerants

Suitable for refrigerants such as ammonia, Freon, and carbon dioxide (compatible with sealing materials).The use of flammable hydrocarbons is not recommended. For more detailedinformation, please contact your local Danfoss sales office.

Pressure

Pressure setting range: 10-40 bar g(145-580 psi g). For more detailed information, please contact yourlocal Danfoss sales office.

Important: The SFA safety valve is a back-pressure-dependent safety valve (if the back pressureexceeds atmospheric pressure, the valve's opening pressure will be higher than the setpressure).In certain situations, such as vibration (which must be avoided), pressure fluctuationsmay cause the valve to close and increase the operating pressure differential.

Pressure Setting

The operating pressure of the refrigeration system must be at least 15% lower than the safety valve's set pressureto ensure the valve reseats properly after activation.

Temperature Range

–30℃ /+100℃ (–22℉ /+212℉ )

Connections

The following connection types are available:

■ External pipe thread T (ISO 228/1)

■ Welded connection (DIN 2448)

Valve Body

The valve body is made of special low-temperature-resistant steel for operation in low-temperature environments.To ensure reliable performance under harsh conditions, the stem, disc, and seat are made ofstainless steel, and the disc gasket is made of special neoprene rubber.

Installation

To ensure proper operation of the safety valve, it must be installed with the spring housingoriented vertically upward. If the valve is used as an internal safety valve and there are no specificrequirements for opening pressure, it may be installed in other orientations. After installation,ensure that the valve is not subjected to static, dynamic, or thermal stresses.

Danfoss has employed various technologies to ensure valve performance, butif foreign matter from the system piping enters the valve body, it may still causedamage to the valve.To prevent contaminants from entering the valve, it is recommended to install an oil-filled U-tubein the discharge branch pipe at the valve's atmospheric outlet.It is also recommended to use the safety valve in conjunction with a double-seat shut-off valve DSV 1 or 2.For more detailed information, please refer to the DSV technical manual.

The SFA is designed according to safety valve standards (DIN3320) and is recommended specifically forrefrigeration systems. When the inlet pressure rises above the set value, the valve initially opens slightly,allowing a small flow of refrigerant.

Recalibration / Maintenance

In some countries, relevant authorities require safety valves to be recalibrated at least once a year(please refer to local regulations).

Control / Identification

After pressure setting at the Danfoss factory, the safety valve is sealed with a lead seal.Therefore, Danfoss guarantees the valve's functionality only if the lead seal remains intact.Each safety valve is equipped with a metal identification plate providing the followinginformation:

- Orifice diameter

- Set pressure

- Production date

- Order code

- Certification type

Transport / Disposal

The safety valve is transported with specially designed protective caps and custom cardboard packaging.

Industry Category
Product Category
Brand: Danfoss
Spec: SFA15T224,SFA15T225
Stock: 100
Manufacturer:
Origin: China / Guangdong / Guangzhoushi
About Toocle.com - Partner Programme - Old Version
Copyright ? Toocle.com. All Rights Reserved.
(浙)-經(jīng)營性-2023-0192
ChatGlobal Chat Now 贵南县| 石城县| 新丰县| 顺昌县| 杨浦区| 西乡县| 旌德县| 特克斯县| 卢龙县| 旬阳县| 金川县| 景宁| 丰顺县| 德化县| 息烽县| 水富县| 岚皋县| 锡林浩特市| 锦州市| 客服| 宽城| 喜德县| 合水县| 江川县| 佛冈县| 合山市| 万州区| 兰州市| 宁城县| 舞阳县| 双鸭山市| 德钦县| 长子县| 历史| 潞城市| 凤冈县| 湖南省| 和林格尔县| 伊春市| 木兰县| 迁西县|