色播婷婷电影综合社区,AV女优不卡亚洲在线,99999AV,日韩人妻中文字幕视频,国产拍自偷,91人人妻,超碰在线81,免费福利视频一区,九草青草原在线看

China Photovoltaic Power Plant Investment Factory Solar Grid-Connected Power Plant EPC - China Supplier
China Photovoltaic Power Plant Investment Factory Solar Grid-Connected Power Plant EPC - China Supplier China Photovoltaic Power Plant Investment Factory Solar Grid-Connected Power Plant EPC - China Supplier China Photovoltaic Power Plant Investment Factory Solar Grid-Connected Power Plant EPC - China Supplier China Photovoltaic Power Plant Investment Factory Solar Grid-Connected Power Plant EPC - China Supplier China Photovoltaic Power Plant Investment Factory Solar Grid-Connected Power Plant EPC - China Supplier

Photovoltaic Power Plant Investment Factory Solar Grid-Connected Power Plant EPC

Price:0.1
Industry Category: Energy
Product Category:
Brand: 芒種
Spec: PV


Contact Info
  • Add:南京市棲霞區(qū)八卦洲街道中心路68號, Zip: 210043
  • Contact: 小芒
  • Tel:15951634545
  • Email:15951634545@163.com

Other Products

Description
Additional Information

Anti-islanding measures and frequency/voltage emergency control devices

(1) Inverter anti-islanding protection

        Inverters must possess anti-islanding protection functionality. The anti-islanding protection for inverters in photovoltaic power plants primarily employs detection methods such as frequency deviation, power variation, and voltage phase jumps, with response times ranging from 100ms to 1s. Islanding phenomenon protection is the most critical and highest-priority protection in grid-connected inverter systems. It is required that the photovoltaic system must cease supplying power to the grid within 2 seconds of grid voltage loss.

(2) Frequency/voltage emergency control device

During islanding phenomena, frequency and voltage undergo abrupt changes. For this phase, a set of frequency/voltage emergency control devices must be installed on the 10kV outgoing line side of the photovoltaic power plant. These devices should feature slip differential blocking functionality and short-circuit judgment capability.

        This frequency/voltage emergency control device is used for emergency grid frequency/voltage control under extreme conditions. It is required for scenarios where abnormal grid frequency/voltage necessitates urgent control measures, such as low-frequency/low-voltage separation or high-frequency generator tripping. The main functional requirements are as follows:

1. Low-frequency/low-voltage separation function: When grid frequency drops to the set value, the device should achieve separation to restore frequency to normal levels. In cases where severe faults or separations occur in grids with significant active power deficits, voltage may drop severely and fail to recover. Low-frequency separation might malfunction under conditions of system reactive power imbalance, making low-voltage separation functionality necessary.

2. High-frequency/high-voltage generator tripping function: When the system experiences over-frequency or over-voltage conditions, the device should be capable of generator tripping, separation, or rapid steam valve control.

3. Out-of-step oscillation separation function: When the power plant loses synchronization with the main system and out-of-step oscillations occur, the device must simultaneously trip all parallel connections between the generating units and the main grid, separating the primary outgoing section of the power plant (i.e., disconnecting both lines; during maintenance, only the operational tie lines are disconnected).

4. Measurement function: The device should simultaneously measure three-phase voltage, three-phase current, frequency, active power, reactive power, and phase angle from two bus sections or two tie lines, serving as the basis for judgment.

5. Remote function: The device must reserve communication interfaces or remote trip contact inputs for executing remote trip commands or load reduction commands; it should also be capable of transmitting load reduction or separation commands remotely.

6. The device should record essential information (such as fault waveform data) and transmit it through interfaces; recorded information must not be lost and should be reproducible. The recorded data is primarily used to determine whether all parts of the device are functioning normally and whether operations are correct.


7. The device should possess automatic time synchronization functionality.

        Jiangsu Mangzhong Construction Co., Ltd. is a comprehensive energy service provider specializing in the photovoltaic field, dedicated to being a smart energy enterprise engaged in photovoltaic power plant investment, development, design, construction, intelligent operation and maintenance, professional consulting services, and photovoltaic equipment recycling.

Company Name: Jiangsu Mangzhong Construction Co., Ltd.

Business Scope: Photovoltaic power plant EPC and solar power station investment

Company Landline: 025-5888 3737

Mobile Number: 159 5163 4545

Company Website: http://www.mangz.cn

Industry Category Energy
Product Category
Brand: 芒種
Spec: PV
Stock: 10000
Manufacturer:
Origin: China / Jiangsu / Nanjingshi
About Toocle.com - Partner Programme - Old Version
Copyright ? Toocle.com. All Rights Reserved.
(浙)-經(jīng)營性-2023-0192
ChatGlobal Chat Me 贞丰县| 石河子市| 平和县| 奇台县| 福海县| 东辽县| 三亚市| 泾川县| 廉江市| 金山区| 长顺县| 分宜县| 武汉市| 家居| 大埔县| 玛纳斯县| 长泰县| 莱芜市| 浙江省| 长子县| 新竹市| 龙川县| 西平县| 宣化县| 阳泉市| 千阳县| 太白县| 东莞市| 西乌珠穆沁旗| 广德县| 阜新| 桃园县| SHOW| 灵石县| 四子王旗| 松桃| 乐平市| 康定县| 乡宁县| 连江县| 白银市|