China C18 Analytical Guard Column Cartridge, Tianjin Chenhang - China Supplier
China C18 Analytical Guard Column Cartridge, Tianjin Chenhang - China Supplier

C18 Analytical Guard Column Cartridge, Tianjin Chenhang

Price:Negotiable
Industry Category:
Product Category:
Brand:
Spec:


Contact Info
  • Add:, Zip:
  • Contact:
  • Tel:
  • Email:

Other Products

Description
Additional Information

In HPLC systems, it cannot be guaranteed that the injected sample will elute. Although the injection volume is small, a portion of the sample always remains at the column head after each injection, which over time can cause the column head to fail. The various reagents used may also contain insoluble or impure substances. Most insoluble matter can be removed by filtering the mobile phase through a frit or membrane filter, but fine particles may pass through the filter. Additionally, after the mobile phase is prepared, there is a possibility of insoluble or impure substances entering from the air, containers, or human contact. Depending on the analytical purpose, these insoluble or impure substances can contaminate the column, cause blockages, or adversely affect the analysis. Installing a guard column before the analytical column can prevent these issues and protect the chromatographic column. This Scienhome guard column assembly combines the strength of stainless steel with the convenience of a PEEK pre-packed cartridge. Without the need for tools, a short guard column with the same packing material as the column is placed between the injection valve and the chromatographic column, which will extend the column's lifespan and ensure reproducible results.

In liquid chromatography (HPLC) experiments, imported HPLC columns from brands such as Agilent, Shimadzu, Waters, Thermo, etc., are commonly used and are expensive. To extend the lifespan of the column, our company supplies a set of C18 guard column assemblies that combine the strength of stainless steel with the convenience of a PEEK pre-packed cartridge. Without the need for tools, a short guard column with the same packing material as the column is placed between the injection valve and the chromatographic column, ensuring reproducible results and effectively preventing residue at the column head, thereby extending the lifespan of the HPLC column. The role of the analytical guard column is to pre-adsorb substances that are strongly adsorbed by the chromatographic column and cannot be washed by the mobile phase. The packing material of the analytical guard column is typically the same as that of the chromatographic column, as damage to the analytical column in most cases only affects a small portion of the packing material at the inlet side.

Part No      Desc.

600220      Guard Column Assembly (Includes Cartridge C18/3 pcs)

600230      Guard Column Assembly (Includes Cartridge C8/3 pcs)

600240      Guard Column Assembly (Includes Cartridge NH2/3 pcs)

600250      Guard Column Assembly (Includes Cartridge Sil/3 pcs)

600260      Guard Column Assembly (Includes Cartridge Phen/3 pcs)

600210      Guard Column Assembly (Includes Cartridge CN/3 pcs)

600221      Guard Column Holder

612111      Cartridge (10/bag), C-18

622111      Cartridge (10/bag), C-8

632111      Cartridge (10/bag), Silica

642111      Cartridge (10/bag), NH2

652111      Cartridge (10/bag), CN

662111      Cartridge (10/bag), Phen

Industry Category
Product Category
Brand:
Spec:
Stock:
Origin: