Dissolved Oxygen Electrode

Price:Negotiable
Industry Category: Instruments & Meters
Product Category:
Brand:
Spec:


Contact Info
  • Add:宜興市高塍鎮(zhèn)江南路126號, Zip: 214214
  • Contact: 余麗蘭
  • Tel:0510-87838003
  • Email:wxzjhb@163.com

Other Products

Description
Additional Information

Introduction to Dissolved Oxygen Electrode Utilizing a polarographic electrode, the anode is made of Ag/AgCl and the cathode of platinum (Pt), with a special electrolyte solution filled between them. The electrode is encapsulated by a silicone rubber permeable membrane. During measurement, a polarization voltage of 675 mV is applied between the electrodes. Oxygen permeates through the membrane and is consumed at the cathode, while an equivalent amount of oxygen is generated at the anode. This dynamic process continues until the oxygen partial pressures on both sides reach equilibrium. At this point, the current between the electrodes is proportional to the oxygen partial pressure. The secondary meter detects this current and, through a series of conversions, obtains the oxygen concentration and content. Simultaneously, an NTC (Negative Temperature Coefficient thermistor) detects the temperature of the measured liquid. The secondary meter samples the data and performs temperature compensation, converting the oxygen concentration or content to values at 25°C. Cathode reaction: O? + 2H?O + 4e? → 4OH? Anode reaction: 4Ag + 4Cl? → 4AgCl + 4e? Applications Dissolved oxygen electrodes can be used to monitor processes where oxygen content affects reaction speed, process efficiency, or the environment, such as in aquaculture, bioreactions, environmental testing (lakes, streams, oceans), water/wastewater treatment, and wine production. The T401ppm dissolved oxygen electrode offers high stability and reliability, suitable for use in harsh environments with minimal maintenance. Troubleshooting When using polarographic electrodes, preheat for at least 15–30 minutes before calibration or measurement. To ensure no bubbles are present in the electrolyte of the membrane, the ASI membrane cap is designed to expel all air from the liquid chamber when installing the membrane head. No bubbles should remain on the membrane surface, as they may be misinterpreted as oxygen-saturated samples. Even when using instruments with automatic temperature compensation, calibrate the electrode at a temperature close to that of the sample solution. Calibrate the electrode in air, using air as the 100% saturated dissolved oxygen reference point. Since the electrode consumes oxygen, the oxygen concentration at the probe surface momentarily decreases. Therefore, it is essential to stir the solution during measurement. Replace the membrane if it is damaged. Technical Parameters: Measurement range: 0–20 mg/L (ppm), 0–200% Operating temperature: 0–130°C Temperature compensation range: 0–130°C Measurement principle: Amperometric sensor Membrane thickness: 50 μm Electrode material: UPVC or 316L Sensing material: POM outer tube, silver tube, gold wire with temperature compensation function Response time: 90% in 60 seconds (upscale, at 20°C) Polarization time: 2 hours Minimum flow rate: 2.5 cm/s Cable length: Standard 10 m Installation method: 3/4-inch pipe thread installation Standard configuration: One electrode, two spare membrane heads, one bottle of specialized electrolyte solution.

Industry Category Instruments & Meters
Product Category
Brand:
Spec:
Stock:
Origin:
About Toocle.com - Partner Programme - Old Version
Copyright ? Toocle.com. All Rights Reserved.
(浙)-經(jīng)營性-2023-0192
ChatGlobal Chat Me 宁晋县| 凤山市| 武乡县| 洛浦县| 光山县| 渝中区| 富源县| 江口县| 洞头县| 水富县| 句容市| 屏东县| 西丰县| 兴宁市| 韩城市| 武强县| 巫溪县| 博兴县| 胶南市| 犍为县| 河池市| 黑龙江省| 北流市| 高青县| 买车| 泗洪县| 呈贡县| 贞丰县| 山阴县| 东明县| 集安市| 永丰县| 汽车| 彰化县| 璧山县| 文山县| 襄汾县| 孟州市| 正安县| 上杭县| 高州市|