China REAL-A4/7.5 Cooling Tower Fan Intelligent Control Cabinet - China Supplier
China REAL-A4/7.5 Cooling Tower Fan Intelligent Control Cabinet - China Supplier

REAL-A4/7.5 Cooling Tower Fan Intelligent Control Cabinet

Price:Negotiable
Industry Category:
Product Category:
Brand:
Spec: REAL-A4/7.5


Contact Info
  • Add:陜西省西安市翠華路60號, Zip:
  • Contact: 劉品宜
  • Tel:13572979371
  • Email:243616989@qq.com

Other Products

Description
Additional Information

REAL-A Central Air Conditioning Energy Saving Cloud Control Management System

1、System Equipment Control and Management

Due to the characteristics of multi-parameter, nonlinearity, and fluctuating cooling/heating loads in central air conditioning systems, it is easy for the system's operating conditions to deviate from the efficient operating state, leading to reduced thermal conversion efficiency of the chiller units. Under the condition of ensuring comfort, to improve the energy efficiency of the central air conditioning system, comprehensive energy efficiency tracking control and management of various components such as chiller units and water circulation systems must be implemented.

2、Chiller Units

Based on the collected supply and return water temperatures, pressure, flow rate, and ambient temperature and humidity of the chilled and cooling water circulation systems, the central air conditioning intelligent controller calculates the actual system load to dynamically adjust the number of operating chiller units and temperature settings. The control mode of chiller units can be divided into two scenarios.

3、Hot Water Circulation

When ambient temperature, humidity, system process parameters, and the heat load at the air conditioning terminals change, the process parameters of the water circulation system also change accordingly. The central air conditioning intelligent controller optimizes the efficiency of the chiller units based on the cooling load value and provides control strategies. The chilled water pump energy efficiency controller dynamically adjusts the chilled water flow rate, the cooling water pump energy efficiency controller dynamically adjusts the cooling water flow rate, the hot water pump energy efficiency controller dynamically adjusts the hot water flow rate, and the cooling tower fan energy efficiency controller adjusts the operating speed of the cooling tower fans to meet the user's heat demand and ensure that the chiller units' COP remains in an efficient conversion state.

4、Energy Management

On the management computer, centralized control and energy efficiency management of system equipment such as chiller units and related electric regulating valves in the water circulation system are achieved. Through intelligent metering units, electricity consumption statistics of the air conditioning system are transmitted via the energy bus to the management computer or other energy statistical management systems, enabling the statistical management of system operating parameters and energy statistical reports.

Specific Models:

REAL-A 1600-J Power Incoming Cabinet

REAL-A2/224.1-K Chiller Unit Feeder Cabinet

REAL-A3/30-2 I Chilled Water Circulation Pump Intelligent Control Cabinet

REAL-A PC System Energy Efficiency Control Main Cabinet

REAL-A3/30-2 Chilled Water Circulation Pump Intelligent Control Cabinet

REAL-A3/15-2 I Hot Water Circulation Pump Intelligent Control Cabinet

REAL-A4/7.5 Cooling Tower Fan Intelligent Control Cabinet

Equipment Product Functions
1. Integrated design of power and control systems, including power distribution, control, frequency conversion, metering, regulation, and a 7-inch human-machine interface.
2. Equipped with international frequency converters capable of suppressing harmonic currents.
3. Built-in intelligent controller (including software).
4. Built-in adaptive optimization model database for cooling water.
5. Controls the start/stop of refrigeration hosts, provides feedback on operational fault signals, collects supply and return water temperatures for host chilled and cooling water, and collects chilled water flow rates for the host.

V. Main Technical Parameters
Operating ambient temperature: 0°C - 40°C
Relative humidity: ≥90% (at 20°C)
Installation altitude: ≤1000m
Input power voltage: Three-phase AC 380V ±38V / Single-phase AC 220V
Input power frequency: 50Hz
Output power: Three-phase AC 0V - 380V
Output frequency: 0Hz - 50Hz
Control cabinet protection rating: IP

Xi'an Yachuan Electric Power Technology Co., Ltd.
Manager Liu
Phone/WeChat: 13572979371 (One Three Five Seven Two Nine Seven Nine Three Seven One)
Welcome to call for discussions!