China DGC-1 Direct Gas Content Measuring Device - China Supplier China DGC-1 Direct Gas Content Measuring Device - China Supplier China DGC-1 Direct Gas Content Measuring Device - China Supplier China DGC-1 Direct Gas Content Measuring Device - China Supplier China DGC-1 Direct Gas Content Measuring Device - China Supplier

DGC-1 Direct Gas Content Measuring Device

Price:Negotiable
Industry Category: Electrical & Power
Product Category:
Brand: 艾迪
Spec: DGC-1


Contact Info
  • Add:高新區(qū)西四環(huán)228號(hào), Zip: 450000
  • Contact: 艾迪
  • Tel:0371-86553011
  • Email:2513586002@qq.com

Other Products

Description
Additional Information

Manufacturer of Direct Gas Content Determination Device DGC-1
The Direct Gas Content Determination Device DGC-1 has currently passed industrial trials at Huainan Mining Bureau and Jincheng Anthracite Mining Group. It uses the core sampling method for determination, with measurement errors significantly smaller than those of the drill cuttings index method. The measurement results show a strong correlation with actual gas emission dynamics and outburst prediction indicators (drill cuttings desorption index and initial gas emission velocity). The equipment's results meet the requirements for predicting coal mine gas emissions and coal-rock dynamic disasters. The technology and accompanying instruments of this achievement have been successfully promoted and applied in various mines of the Huainan Mining Bureau in China.
Product Introduction of Direct Gas Content Determination Device DGC-1
The Direct Gas Content Determination Device DGC-1 is primarily used for determining the original gas content of coal seams and the original desorbable gas content of coal seams. It can be applied in gas emission prediction, outburst risk assessment for working faces and regions, evaluation of pre-drainage gas effects, and the compilation of gas geological maps. By directly drilling underground to extract coal cores at predetermined depths, the gas desorption rate and desorption volume of the coal cores are measured. A specific mathematical model is used to calculate the gas loss before the coal sample is sealed in the sample cylinder. Laboratory measurements of relevant parameters are then used to calculate the original gas content and original desorbable gas content. This process and equipment feature short measurement times, generally less than 8 hours; reduced engineering workload compared to indirect methods for determining coal seam gas content, resulting in lower costs; minimal influence from geological structures on measurement location selection, allowing for point measurements; and high reliability and accuracy, with precision exceeding gas content measurements during geological exploration.
Technical Parameters of Direct Gas Content Determination Device DGC-1
1 Underground Core Sampling System and Underground Desorption System
Core tube diameter: ¢73, ¢90
Number of multiple samples per extraction: 5
Core drilling inclination angle: >0°
Required desorption time underground: 30min
Underground desorption tube range: 800ml
Underground desorption tube accuracy: 2ml
2 Surface Gas Desorption System
Power supply: 220V
Desorption tube accuracy: 2ml
Desorption tube range: 1000ml/tube, 1500ml/tube
Micro vacuum pump air extraction rate: 3L/min
Micro vacuum pump vacuum degree: 65KPa
Thermometer: -50~0~500℃
Electronic barometer: 977hPa~1050hPa
3 Weighing System
Weighing capacity: 3000g
Sensitivity: 0.1g
Tare range: 3000g
Stabilization time: <3S
Weighing pan diameter: ¢130mm
Ambient temperature: 5~35℃
Power supply voltage: 220v(+10%~-15%)
Power consumption: 5W
4 Coal Sample Crushing System
Material of mortar: High manganese steel
Feed particle size: ≤26mm
Discharge particle size: 80-200 mesh
Working power supply: 220V, 50HZ
Feed quantity per batch: ≤1000g/mortar
Crushing time: 3-5min
Total machine weight: 160Kg
Motor power: 1.5KW
5 Moisture Determination System
Load: 110g
Graduation value: 5mg
Differential scale reading range: 0~1 
Moisture determination accuracy: ±0.2g%
Temperature adjustment range: 75℃~160℃
Weighing pan diameter: ¢100mm
Power supply and power consumption: 220V   50HZ    260W
6 Data Processing System
Software operating environment: This software runs on Windows XP and Win7 systems.
Main software functions: User management, data process report output, experimental result report output, gas content W value calculation, desorbable gas content Wa, residual gas content Wc calculation, gas pressure P calculation, cumulative gas desorption volume Q calculation, report output, printing, and help.

Industry Category Electrical & Power